Skip to main content

Table 1 Costs and CRT device runtime

From: A long-term cost-effectiveness analysis of cardiac resynchronisation therapy with or without defibrillator based on health claims data

Input parameter

Mean

SD

PSA distribution

Costs in €

 

Implantation CRT-P

11,092.44

2807.39

Gamma

Implantation CRT-D

16,648.03

2857.33

Gamma

Replacement CRT-P

5643.52

1209.20

Gamma

Replacement CRT-D

8095.18

1123.75

Gamma

Heart failure hospitalisation

4077.23

2611.73

Gamma

Quarterly outpatient costs

49.25

47.98

Gamma

Monthly medication costs

180.82

205.54

Gamma

Future medical costs unrelated to HF (65–84 years)

7275

–

–

Future medical costs unrelated to HF (older 85 years)

16,616

–

–

Device longevity in months

   

CRT-P

98*

–

Poisson

CRT-D

72*

–

Poisson

  1. CRT-P: cardiac biventricular pacemaker, CRT-D: cardiac biventricular defibrillator, HF: heart failure, SD: standard deviation, PSA: probabilistic sensitivity analysis
  2. *Median